CGQNF - NICKEL CADMIUM CELL
- MSDS: CGQNF
- Manufacturer: BATTERY ASSEMBLERS INC
- Product Name: NICKEL CADMIUM CELL
- National Stock Number: 6140-00N083570
Product Identification
Product ID:NICKEL CADMIUM CELL
MSDS Date:06/12/1992
FSC:6140
NIIN:00N083570
MSDS Number: CGQNF
Responsible Party
BOHEMIA, NY 11716
US
Emergency Phone: 516-567-8855
Info Phone: 516-567-8855
Preparer: ROBERT MAINZER
Cage: 0B0Y5
Contractor
Telephone: 516-567-8855/8278
Cage: 0B0Y5
Ingredients
CADMIUM HYDROXIDE
CAS: 21041-95-2
RTECS: EV1260000
Fraction By Weight: 11-26%
OSHA PEL 0.05 MG CD/M3
ACGIH TLV: 0.05 MG CD/M3
NICKEL (II) HYDROXIDE (SARA 313) (CERCLA)
CAS: 12054-48-7
RTECS: QR7040000
Fraction By Weight: 5-12%
OSHA PEL 1 MG(NI)/M3
ACGIH TLV: 0.1 MG(NI)/M3
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
NICKEL POWDER
Fraction By Weight: 8-17%
OSHA PEL 1 MG/M3 (MFR)
ACGIH TLV: 1 MG/M3 (MFR)
POTASSIUM HYDROXIDE (CERCLA)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: <30%
OSHA PEL C 2 MG/M3
ACGIH TLV: C 2 MG/M3
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
LITHIUM HYDROXIDE
CAS: 1310-65-2
RTECS: OJ6307070
Fraction By Weight: <0.2%
OSHA PEL N/K
ACGIH TLV: N/K
THE NATIONAL INSTITUTE OF INDUS HLTH
RTECS: 9999999ZZ
HEIGHT, ERYTHROCYTE COUNTS & CIRCULATORY DEFECTS
RTECS: 9999999ZZ
WITH ELEVATED URINE PROTEIN CONCENTRATION) AND LIVER
RTECS: 9999999ZZ
APPLY INSULATING MATL TO ASSEMBLY WORK SURF. THIS
RTECS: 9999999ZZ
& CAPACITY OF BATTERIES DUE TO SELF-DISCHARGE DURING
RTECS: 9999999ZZ
USE. OBSERVE SPECIFIED CHARGE RATE SINCE HIGHER
RTECS: 9999999ZZ
CELL RUPTURE AND/OR VENT.
RTECS: 9999999ZZ
AND FULL LENGTH FACESHIELD .
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGEST: IF BATTERY SHOULD OPEN
IN DIGESTIVE TRACT, ELECTROLYTE MAY CAUSE LOCALIZED BURNS. CONTENTS
INCL CADMIUM COMPONENTS WHICH MAY CAUSE CHOKING, SALIVATION, NAUS,
DIARR, PERSISTENT VOMIT, AB DOM PAIN, FAINTNESS, DIZZ & POSS LIVER
& KIDNEY INJURY. SKIN ABSORPTION: NO EVIDENCE OF ADVERSE EFTS (EFTS
OF OVEREXP)
Explanation of Carcinogenicity:CADMIUM HYDROXIDE: IARC MONO, VOL 58, PG
119, 1993: GROUP 1. NICKEL: IARC MONO, VOL 49, PG 257, 1990: GROUP
2B.(SUP DAT)
Effects of Overexposure:HLTH HAZ: FROM ANY AVAIL INFO. INHAL:
DUST/PARTICLES MAY CAUSE RESP IRRIT, HDCH, NAUS & VOMIT. SKIN CONT:
OPENED BATTERY MAY CAUSE CHEM BURNS. EYES: OPENED BATTERY MAY CAUSE
SEV IRRIT & CHEM BURNS. CH RONIC: RECENT LAB EXPT HAS SHOWN REPRO
TOXICITY OF CADMIUM. (ING 6)
Medical Cond Aggravated by Exposure:A KNOWLEDGE OF THE AVAILABLE
TOXICOLOGY INFORMATION AND OF THE PHYSICAL AND CHEMICAL PROPERTIES
OF THE MATERIAL SUGGEST THAT OVEREXPOSURE IS UNLIKELY TO AGGRAVATE
EXISTING MEDICAL CONDITIONS.
First Aid
First Aid:INGESTION: DO NOT INDUCE VOMITING. SEEK MEDICAL ATTENTION
IMMEDIATELY. INHALATION: REMOVE TO FRESH AIR. EYES: IMMEDIATELY
FLUSH THOROUGHLY WITH WATER AND CONTINUE FLUSHING FOR AT LEAST 15
MINUTES. SEE K MEDICAL ATTENTION. SKIN: FLUSH WITH COPIOUS AMOUNTS
OF WATER. SEE MD .
Fire Fighting
Extinguishing Media:IN CASE OF FIRE IN ADJACENT AREA, USE ANY CLASS OF
EXTINGUISHING MEDIUM ON THESE BATTERIES OR THEIR PACKING MATERIAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:CADMIUM FUMES MAY BE RELEASED DURING
BURNING.
Accidental Release
Spill Release Procedures:NONE SPECIFIED BY MANUFACTURER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN COOL PLACE, BUT PVNT
CONDENSATION OF CELL/BATTERY TERMINALS. ELEVATED TEMP CAN RSLT IN
SHORTENED BATTERY LIFE. STORE BETWEEN -30C AND 35C.
Other Precautions:ACCIDENTAL SHORT CIRCUIT WILL BRING HIGH TEMP
ELEVATION TO BATTERY AS WELL AS SHORTEN BATTERY LIFE. BE SURE TO
AVOID PRLNG SHORT CIRCUIT, SINCE HEAT CAN BURN ATTENDENT SKIN &
EVEN RUPTURE. BATTERIES P ACKAGED IN BULK CONTRS SHOULD (SUP DAT)
Exposure Controls
Respiratory Protection:NOT REQUIRED UNDER CONDITIONS OF NORMAL USE. USE
NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NOT REQUIRED UNDER CONDITIONS OF NORMAL USE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGG (ING 13)
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN: NTP 7TH ANNUAL RPT ON CARCINS, 1994: ANTIC TO BE
CARCIN. ANIMAL: LUNG. NICKEL HYDROXIDE: NTP 7TH ANNUAL RPT ON
CARCINS, 1994: ANTIC TO BE CARCIN. ANIMAL: LUNG. OTHER PREC: NOT BE
JUM BLED. METAL COVERED TABLES/BELTS USED FOR ASSEMBLY OF BATTERIES
INTO DEVICES CAN BE SOURCE OF SHORT CIRCUITS. (ING 9)
Chemical Properties
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Disposal
Waste Disposal Methods:DO NOT INCINERATE OR SUBJECT CELLS TO
TEMPERATURES IN EXCESS OF 100C (212F). SUCH TREATMENT CAN VAPORIZE
THE LIQUID ELECTROLYTE AND CAUSE CELL RUPTURE. DISPOSE OF IN
ACCORDANCE WITH LOCAL, STATE AND F EDERAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.